Laboratory Countertops, Sinks, and Plumbing
Fume Hood Sinks & Plumbing Services

Laboratory Countertops, Sinks & Plumbing


High-Performance Laboratory Worksurfaces & Plumbing Systems

HEMCO offers a complete line of laboratory countertops, sinks, and plumbing systems designed to support applications ranging from light-duty laboratory work to environments exposed to acids, solvents, and corrosive materials.

Available in multiple materials and configurations, these systems are engineered to meet performance, durability, and safety requirements across research, education, healthcare, and industrial laboratories.

HEMCO’s technical team can also assist in selecting the appropriate materials and configurations to meet your specific laboratory needs.


Laboratory Countertops

(UniFlow SE, LE hoods only) Epoxy Resin
(UniFlow SE, LE hoods only) Epoxy Resin, color: black, 1-1/4” thick, 3/8” dished

Epoxy Resin Worksurfaces are recommended for general laboratory work where greater chemical resistance is required. Surface is dished 3/8" to contain spillage. Worksurface is cast of thermosetting epoxy resin, creating a molded solid 1-1/4" thick top which is extremely hard, abrasion and heat resistant. Tested to UL 1805 classification.

Size

Cat. No.

Size

Cat. No.

36”W x 30”D

20315

36”W x 36”D

20325

48”W x 30”D

20415

48”W x 36”D

20425

60”W x 30”D

20515

60”W x 36”D

20525

72”W x 30”D

20615

72”W x 36”D

20625

96”W x 30”D

20815

96”W x 36”D

20825

(UniFlow SE, LE hoods only) Phenolic Resin
(UniFlow SE, LE hoods only) Phenolic Resin, color: black, 1-1/4" thick

Phenolic Resin Worksurface are recommended for general laboratory work where high concentrations of solvent, acids and alkalies are being worked with. Work surface combines excellent chemical resistance scratch and wear resistance. Surface is flat 1-1/4" thick.Tested to UL 1805 classification.

Size

Cat. No.

Size

Cat. No.

36”W x 30”D

20315

36”W x 36”D

20325

48”W x 30”D

20415

48”W x 36”D

20425

60”W x 30”D

20515

60”W x 36”D

20525

72”W x 30”D

20615

72”W x 36”D

20625

96”W x 30”D

20815

96”W x 36”D

20825

(UniFlow SE, LE hoods only) Stainless Steel
(UniFlow SE, LE hoods only) Stainless Steel, satin finish, 1-1/4” edge, 3/8” dished

Stainless Steel Fume Hood Worksurfaces are fabricated of type 304,16 gauge steel with #3 satin finish. Surface is dished 3/8” to contain spillage. All corners, ends, and joints are continuous 1-1/4” heliarc welded and ground smooth. Type 316 stainless steel is also available.

Size

Cat. No.

Size

Cat. No.

36”W x 30”D

20315

36”W x 36”D

20325

48”W x 30”D

20415

48”W x 36”D

20425

60”W x 30”D

20515

60”W x 36”D

20525

72”W x 30”D

20615

72”W x 36”D

20625

96”W x 30”D

20815

96”W x 36”D

20825


Fume Hood Laboratory Sinks

A complete line of sinks in epoxy resin, polypropylene, and stainless steel.

Epoxy Resin Sink
Epoxy Resin Sink

Laboratory sink made of chemical and corrosion resistant epoxy resin. Drop-in sink. color: black. Specify location. Includes stopper & drain outlet.

Size

Cat. No.

9” x 6” x 6” deep

42021

16” x 12” x 8” deep

42022

18” x 15” x 11” deep

42026

24” x 16” x 8” deep

42027

Polypropylene Sink
Polypropylene Sink

Made of chemical resistant heavy duty polypropylene. Drop-in sink. color: black. Please specify desired location. Includes drain outlet.

Size

Cat. No.

12” x 8” x 8” deep

72041

14” x 10” x 6” deep

72043

18” x 15” x 12” deep

72045

28” x 20” x 9” deep

72048

Stainless Steel Sink
Stainless Steel Sink

Made of one-piece, type 304 stainless steel & polished to a No. 4 satin finish. Drop-in sink. Underside is sound deadened to reduce drumming. Specify location. Includes drain outlet.

Size

Cat. No.

12” x 12” x 7.5” deep

42031

16” x 16” x 7.5” deep

42032

16” x 22” x 7.5” deep

42033

16” x 28” x 7.5” deep

42034


Fume Hood Cupsinks

Cupsink 6” Diameter
Cupsink 6” Diameter

Polypropylene cupsink with 1-1/2” IPS tailpiece and outlet strainer.

Cat. No. 40118

Oval Cupsink
Oval Cupsink

Drop-in oval cupsink in polypropylene. 1-1/2” IPS tailpiece includes strainer.

3" X 6" Cat. No. 40119
3" X 9" Cat. No. 40121

Oval Wall Cupsink
Oval Wall Cupsink

6” x 3”, Cupsink is made of polypropylene with 1-1/2” IPS tailpiece and outlet strainer. Optional on FM fume hoods.

Cat. No. 40419

Round Cupsink
Round Cupsink

9” Diameter, Cupsink is made of epoxy with 1-1/2” IPS tailpiece and outlet strainer.

Cat. No. 40519


Pegboard, P-Traps & Fume Hood Neutralization Tanks

Jar P-Trap
Jar P-Trap

P-trap includes adjustable tailpiece and removable jar. 1-1/2” IPS tail piece.

Cat. No. 40220

P-Trap
P-Trap

P-trap is made of polypropylene with 1-1/2” IPS tailpiece.

Cat. No. 40120

Phenolic Resin Pegboards
Phenolic Resin Pegboards

For drying and storage of lab ware. Pegboard in 1” thick and includes a stainless steel drip trough to collect run-off.

Width

Height

No. of Pegs

Cat. No.

24”

30”

39

72430

30”

30”

46

73030

30”

36”

60

73036

Neutralization Tanks
Neutralization Tanks

Molded of one-piece,chemical resistant polyolefin, neutralization tanks are designed to dilute and neutralize laboratory waste and concentrated corrosives. Limestone is utilized as the medium for neutralizing the hazardous waste. Note: limestone is not included with tank.

Description

Cat. No.

5 gallon tank (5.5” wide x 14” deep x 20” high with 1-1/2” IPS inlet/outlet) Note: 5 gallon tank requires (1) bag of limestone.

40222

15 gallon tank (17.25” dia. x 15.5” H with 1-1/2” IPS inlet/outlet) Note: 15 gallon tank requires (3) bags of limestone.

40322

Limestone is utilized as the medium for neutralizing the hazardous waste. (50 lb bag) Note: Limestone is not included with tank.

40223


Fire Extinguishers

Foremost: fume hood fires must be extinguished promptly, failure to do so could result in loss of life and valuable equipment & processes. In case of a fire inside of a fume hood, 1. Lower the sash into the closed position. 2. Pull the manual front mount discharge cable to activate the fire extinguisher. 3. Shut off the fume hood blower on the fume hood, and any remote exhaust blowers that are connected. 4. Shut off any utility services that could feed a fire. Fire extinguisher activation occurs at 165° Fahrenheit. These are recommendations, contact your laboratory safety officer for guidelines.

ABC Dry Chemical Fire Extinguishers
ABC Dry Chemical Fire Extinguishers

Fire Extinguisher with automatic activation at 165° Fahrenheit. With dry chemical Monoammonium Phosphate, 10 lb.

Cat No. 53030

ABC Dry Chemical Fire Extinguishers
ABC Dry Chemical Fire Extinguishers

Fire Extinguisher with automatic activation at 165° Fahrenheit.

With Halon, up to 50 Cubic feet
Cat No. 53050

With Halon, 125 Cubic feet
Cat No. 53125

Manual Discharge Cable Kit
Cat No. 53007

Manual discharge cable kit Note: Larger hoods may require (2) or more extinguishers, based on interior cubic dimensions.

Expert Help for Your Laboratory Needs

HEMCO’s team can help you select the right countertop materials, sink configurations, and plumbing systems for your laboratory environment.

Contact Us Today