Clean Aire II Ductless Fume Hoods
Clean Aire II Fume Hoods shown with options

Clean Aire II Ductless Fume Hoods


HEMCO Clean Aire II Ductless Fume Hoods provide safe and efficient filtration of fumes, odors, and non-hazardous chemical vapors without the need for external ductwork.

These self-contained systems use activated carbon filtration to capture contaminants and recirculate clean air back into the laboratory, reducing installation costs and increasing flexibility.


Clean Aire II Ductless Fume Hoods Diagram

Clean Aire II Specs

Dimension

24”

30”

36”

48”

Width “A”

24”

30”

36”

48”

Width ”B”

18”

24”

30”

42”

Sash Height “C”

20”

20”

20”

20”

Height “D”

36”

36”

36”

36”

Depth “E”

23”

23”

23”

23”


Clean Aire II Ductless Fume Hoods

Size

24”

30”

36”

48”

Hood Cat. No.

92025

93025

90325

90425

Phenolic Worksurface Cat. No.

92028

93028

90328

90428

Replacement Filter Cat. No.

52004 (1) required

52004 (1) required

52004 (2) required

52004 (2) required

Optional Accessories

Name

Description

Cat. Number

Base Table

Constructed of coated welded steel 48" wide X 30" deep. Adjustable height from 30" to 36". Table includes a foot rail, and leveler feet.

54821

Plastic Laminate Worksurface

48" X 30"

20428

Replacement Carbon Filter

Carton of 2

52004


Mobile Tables

Mobile Tables


Clean Aire II Fume Hoods are a Class DH1 ductless hood workstation. Activated Carbon Filtration for fumes, odors, non-hazardous chemical vapors. See your MSDS data sheet for specific details of each chemical used.

Key Features:

  • Available in 38" and 48" wide models

  • Adjustable height and fixed height options

  • 30" standard height

  • Welded 1" × 2" 16-gauge rectangular tubing construction

  • Four 250 lb. capacity casters — two lockable

  • Chemical-resistant plastic laminate work surface with matte finish and black perimeter edge bumper

  • Powder-coated finish in Pearl White


Mobile Table Specifications

Mobile Table Specifications

HEMCO Mobile table is designed to hold:

  • MicroFlow I Workstations

  • MicroFlow II Workstations

  • MicroFlow III Workstations

  • Demonstration Hoods

  • VSE Vented safety enclosures

  • Table top fume hoods

Catalog Number

Width "A"

Height "B"

Depth "C"

50315 Fixed Height

38”

30”

24”

50415 Fixed Height

48”

30”

30”

70415 Fixed Height

 

 

 

50403 Adjustable Height

48”

36”

24”

70318 Adjustable Height

36”

28.5”- 38.5”

24”

70418 Adjustable Height

48"

28.5”- 38.5”

30”

Start Your Next Project Today

Our team can help determine if a ductless filtration system is right for your application and recommend the appropriate Clean Aire II configuration.

Contact Us Today