Clean Aire II Ductless Fume Hoods
HEMCO Clean Aire II Ductless Fume Hoods provide safe and efficient filtration of fumes, odors, and non-hazardous chemical vapors without the need for external ductwork.
These self-contained systems use activated carbon filtration to capture contaminants and recirculate clean air back into the laboratory, reducing installation costs and increasing flexibility.
Clean Aire II Specs
Dimension | 24” | 30” | 36” | 48” |
Width “A” | 24” | 30” | 36” | 48” |
Width ”B” | 18” | 24” | 30” | 42” |
Sash Height “C” | 20” | 20” | 20” | 20” |
Height “D” | 36” | 36” | 36” | 36” |
Depth “E” | 23” | 23” | 23” | 23” |
Clean Aire II Ductless Fume Hoods
Size | 24” | 30” | 36” | 48” |
|---|---|---|---|---|
Hood Cat. No. | 92025 | 93025 | 90325 | 90425 |
Phenolic Worksurface Cat. No. | 92028 | 93028 | 90328 | 90428 |
Replacement Filter Cat. No. | 52004 (1) required | 52004 (1) required | 52004 (2) required | 52004 (2) required |
Optional Accessories
Name | Description | Cat. Number |
|---|---|---|
Base Table | Constructed of coated welded steel 48" wide X 30" deep. Adjustable height from 30" to 36". Table includes a foot rail, and leveler feet. | 54821 |
Plastic Laminate Worksurface | 48" X 30" | 20428 |
Replacement Carbon Filter | Carton of 2 | 52004 |
Mobile Tables
Clean Aire II Fume Hoods are a Class DH1 ductless hood workstation. Activated Carbon Filtration for fumes, odors, non-hazardous chemical vapors. See your MSDS data sheet for specific details of each chemical used.
Key Features:
Available in 38" and 48" wide models
Adjustable height and fixed height options
30" standard height
Welded 1" × 2" 16-gauge rectangular tubing construction
Four 250 lb. capacity casters — two lockable
Chemical-resistant plastic laminate work surface with matte finish and black perimeter edge bumper
Powder-coated finish in Pearl White
Mobile Table Specifications
HEMCO Mobile table is designed to hold:
MicroFlow I Workstations
MicroFlow II Workstations
MicroFlow III Workstations
Demonstration Hoods
VSE Vented safety enclosures
Table top fume hoods
Catalog Number | Width "A" | Height "B" | Depth "C" |
|---|---|---|---|
50315 Fixed Height | 38” | 30” | 24” |
50415 Fixed Height | 48” | 30” | 30” |
70415 Fixed Height |
|
|
|
50403 Adjustable Height | 48” | 36” | 24” |
70318 Adjustable Height | 36” | 28.5”- 38.5” | 24” |
70418 Adjustable Height | 48" | 28.5”- 38.5” | 30” |
Start Your Next Project Today